| REGUALTOR |
 |
CHARACTERISTICS |
 |
SENSORS |
 |
FUNCTIONS |
XR20CX
 |
 |
Digital Controller on/off
Out: 1 reley
|
 |
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
|
 |
- digital settings
- functional in applications for heating / cooling
- configurable digital inputs (door alarm)
- icing by stopping the compressor
- reducing energy consumption function Save Energy
- quick programing with HOTKEY function
- TTL output that allows connection to monitoring systems Xweb
|
XR60CX
 |
 |
Digital Controller on/off
Out: 3 reley
|
 |
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
|
 |
- digital settings
- functional in cold applications
- ensure control of the compressor icing and ventilation
- configurable digital inputs (door alarm)
- reducing energy consumption function Save Energy
- quick programing with HOTKEY function
- TTL output that allows connection to monitoring systems Xweb
|
XT121C
 |
 |
Multifunctional digital Controller temperature in 2 steps
Out: 3 relays
|
 |
NTC /PTC PT1000/ termocuple
|
 |
- digital settings
- functional in applications for heating / cooling
- reducing energy consumption function Save Energy
- quick programing with HOTKEY function
- TTL output that allows connection to monitoring systems Xweb
|
WING XW60K

 |
 |
Split digital controller
on/off
Out:4 relays
|
 |
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
|
 |
- digital settings
- functional in cold applications
- ensures the control of the compressor, icing, ventilation and lighting
- special digital input for door
- Configurable input for external alarms, starting icing,
- allows remote connection with V620 keypad or CX620
- reducing energy consumption function Save Energy
- quick programing with HOTKEY function
- TTL output that allows connection to monitoring systems Xweb
|
XH260L
 |
 |
Compact digital controller
Out:6 relays
|
 |
NTC:NG6 –40C-+100C
XH20P: 0…99%RH, 4…20mA Out
|
 |
- digital settings
- functional in applications for heating / cooling
- ensures the control of the compressor, icing, ventilation and lighting, the resistances of a heating and humidifying / dehumidification equipment
- special digital input for door
- Configurable input for external alarms, start icing, on / off,
- reducing energy consumption function Save Energy
- quick programing with HOTKEY function
- TTL output that allows connection to monitoring systems Xweb
|
XLR170
 |
 |
Compact controller
Out:6 relays
|
 |
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
|
 |
- compact solution to drive an installation phase of max 4kW
- special for cold applications
- digital settings
- ensure control of the compressor icing and ventilation
- equipped with auxiliary outputs for alarms and lighting
- reducing energy consumption function Save Energy
- quick programing with HOTKEY function
- TTL output that allows connection to monitoring systems Xweb
|
XJP60D
 |
 |
Temperature acquisition module
|
 |
NTC:NG6 –40C-+100C
PTC: S6SH –50C-+150C
|
 |
- 6 inputs for temperature sensors
- 3 programmable digital inputs
- Connection X-REP / Hot Key
- Built-in RS485 serial output
|